| Section 1.0 Gas Detection Sensor Assemblies | |
| Section 1.1 Model Series 700 Gas Detection Sensors (Does not include junction box. | |
| See section 1.1.7 for junction box adder instructions.) | |
| 1.1.1 Combustible Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 967-525520-100 | FP-700 Catalytic Combustible Gas Sensor Assembly |
| 967-215520-100 | IR-700-CH Infrared Combustible Hydrocarbon Sensor Assembly |
| 1.1.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 967-015520-100 | TP-700 Solid State MOS H2S Sensor Assembly |
| 967-242490-100 | DM-700-H2S Electro Chemical H2S Sensor Assembly |
| 1.1.3 Oxygen Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 967-345520-025 | DM-700-O2 Oxygen Deficiency Sensor Assembly |
| 1.1.4 VOC Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 967-P15520-010 | PI-700-VOC Volatile Organic Compound Sensor Assembly |
| 967-P25520-01K | PI-701-VOC Volatile Organic Compound Sensor Assembly |
| 1.1.5 Carbon Dioxide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 967-405520-005 | IR-700-CO2 Infrared Sensor Assembly - Low Range (0-5%) |
| 967-425520-025 | IR-700-CO2 Infrared Sensor Assembly - High Range (10-100%) |
| 1.1.6 Electrochemical Toxic Gas Detection Sensor Assemblies | |
| Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | |
| Part Number | Model Number - Description |
| 967-12EA90-100 | DM-700-C2H3O Acetyldehyde Sensor Assembly |
| 967-12EG90-100 | DM-700-C2H2 Acetylene Sensor Assembly |
| 967-12EM90-100 | DM-700-C3H3N Acrylonitrile Sensor Assembly |
| 967-505090-100 | DM-702-NH3 Ammonia Sensor Assembly |
| 967-191990-001 | DM-700-AsH3 Arsine Sensor Assembly |
| 967-747590-005 | DM-700-Br2 Bromine Sensor Assembly |
| 967-12EB90-100 | DM-700-C4H6 Butadiene Sensor Assembly |
| 967-444490-100 | DM-700-CO Carbon Monoxide Sensor Assembly |
| 967-747490-010 | DM-700-CL2 Chlorine Sensor Assembly |
| 967-777790-001 | DM-701-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) |
| 967-747690-050 | DM-700-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) |
| 967-192190-005 | DM-700-B2H6 Diborane Sensor Assembly |
| 967-12EO90-100 | DM-700-C2H5OH Ethanol Sensor Assembly |
| 967-24EZ90-100 | DM-700-C2H5SH Ethyl Mercaptans Sensor Assembly |
| 967-12ED90-100 | DM-700-C2H4 Ethylene Sensor Assembly |
| 967-12EJ90-100 | DM-700-C2H4O Ethylene Oxide Sensor Assembly |
| 967-272790-001 | DM-700-F2 Fluorine Sensor Assembly |
| 967-12EP90-100 | DM-700-CH2O Formaldehyde Sensor Assembly |
| 967-232590-002 | DM-700-GeH4 Germane Sensor Assembly |
| 967-262690-001 | DM-700-N2H4 Hydrazine Sensor Assembly |
| 967-848490-100 | DM-700-H2 Hydrogen Sensor Assembly (ppm Range) |
| 967-050590-04P | DM-701-H2 Hydrogen Sensor Assembly (4% Range) |
| 967-070790-01P | DM-702-H2 Hydrogen Sensor Assembly (1% Range) |
| 967-090890-030 | DM-700-HBr Hydrogen Bromide Sensor Assembly |
| 967-090990-030 | DM-700-HCL Hydrogen Chloride Sensor Assembly |
| 967-131390-030 | DM-700-HCN Hydrogen Cyanide Sensor Assembly |
| 967-333390-010 | DM-700-HF Hydrogen Fluoride Sensor Assembly |
| 967-242490-100 | DM-700-H2S Hydrogen Sulfide Sensor Assembly |
| 967-12EE90-100 | DM-700-CH3OH Methanol Sensor Assembly |
| 967-24EK90-100 | DM-700-CH3SH Methyl Mercaptans Sensor Assembly |
| 967-949490-100 | DM-700-NO Nitric Oxide Sensor Assembly |
| 967-646490-010 | DM-700-NO2 Nitrogen Dioxide Sensor Assembly |
| 967-393990-001 | DM-700-O3 Ozone Sensor Assembly |
| 967-414190-001 | DM-700-COCL2 Phosgene Sensor Assembly |
| 967-192090-005 | DM-700-PH3 Phosphine Sensor Assembly |
| 967-232390-050 | DM-700-SiH4 Silane Sensor Assembly |
| 967-555590-020 | DM-700-SO2 Sulfur Dioxide Sensor Assembly |
| 967-12EF90-100 | DM-700-C4H6O2 Vinyl Acetate Sensor Assembly |
| 967-12EL90-100 | DM-700-C2H3CL Vinyl Chloride Sensor Assembly |
| 1.1.7 Model Series 700 Junction Box Adder | |
| Todetectionorder asensormodelwith700 agas | |
| junctionpart numberbox,ofmodifythe sensorthe | |
| (s)theyouinstructionswant accordingbelow. to | |
| Catalytic Combustible, Solid State H2S, Oxygen, VOC, & CO2 | |
| With aluminum junction box, indicate a "1" in position 6 of the PN (xxx-xx1xxx-xxx) | |
| With stainless steel junction box, indicate a "4" in position 6 of the PN (xxx-xx4xxx-xxx) | |
| Electrochemical: NOTE: Detcon recommends selection of the 316SS J-box for strong | |
| acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | |
| With aluminum junction box, indicate a "1" in position 9 of the PN (xxx-xxxxx1-xxx) | |
| With stainless steel junction box, indicate a "4" in position 9 of the PN (xxx-xxxxx4-xxx) | |
| 1.1.8 Model Series 700 Integration Modules | |
| Part Number | Model Number - Description |
| 975-70000A-00A | Remote Control / Alarm Relay Module in Aluminum Enclosure Class |
| 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000A-00S | Remote Control / Alarm Relay Module in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000H-00A | Remote Control / Alarm Relay Module with Hart in Aluminum |
| Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000H-00S | Remote Control / Alarm Relay Module with Hart in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000P-00A | Remote Control / Alarm Relay Module with Profibus in Aluminum |
| Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000P-00S | Remote Control / Alarm Relay Module with Profibus in 316SS |
| Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70000F-00A | Remote Control / Alarm Relay Module with Foundation Fieldbus in |
| Aluminum Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group | |
| 975-70000F-00S | Remote Control / Alarm Relay Module with Foundation Fieldbus in |
| 316SS Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group | |
| 975-70005H-00A | Hart Integration Module in Aluminum Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70005H-00S | Hart Integration Module in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70005P-00A | Profibus Integration Module in Aluminum Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70005P-00S | Profibus Integration Module in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70005F-00A | Foundation Fieldbus Integration Module in Aluminum Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 975-70005F-00S | Foundation Fieldbus Module in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 976-000321-000 | Wireless Integration RXT 320 in Aluminum Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 976-000322-000 | Wireless Integration RXT 320 in 316SS Enclosure |
| Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | |
| 1.1.9 Model Series 700 Spare Parts - Universal | |
| Part Number | Model Number - Description |
| 613-120000-700 | Sensor splash guard with integral cal-port |
| 327-000000-000 | Magnetic programming tool |
| 975-000020-893 | Sensor duct mount kit – 700 Series |
| 960-202200-000 | Condensation prevention packet (for J-Box replace annually) |
| 500-003087-100 | Transient Protection Module |
| 437-500000-000 | Stainless steel tag |
| 943-004223-000 | 2" pipe mount with sun shade |
| 943-004221-000 | Sensor Mounting Plate for 2" pipe |
| 897-850000-010 | Standard aluminum junction box with solid lid |
| 897-850901-010 | Standard aluminum junction box with lens cover |
| 897-850000-316 | Stainless steel junction box with solid cover |
| 897-850901-316 | Stainless steel junction box with lens cover |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 943-003436-000 | Harsh location water guard |
| 943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard |
| 943-001747-SS5 | Stainless steel flow through adapter |
| 1.1.10 Spare Parts - FP-700 Catalytic Combustible Gas Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-525500-100 | FP-700 Catalytic Combustible Gas (ITM) |
| 602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor |
| 370-201600-700 | Combustible Gas plug-in sensor for FP-700 |
| 1.1.11 Spare Parts - IR-700-CH Infrared Combustible Hydrocarbon Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-215500-100 | IR-700-CH Infrared Combustible Hydrocarbon (ITM) |
| 602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor |
| 370-3658CH-700 | Combustible Hydrocarbon plug-in sensor for IR-700-CH |
| 1.1.12 Spare Parts - TP-700 Solid State MOS H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-015500-100 | TP-700 Solid State MOS H2S (ITM) |
| 602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor |
| 370-010000-700 | Solid State MOS H2S plug-in sensor for TP-700 |
| 1.1.13 Spare Parts - DM-700-H2S Electro Chemical H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-245500-000 | DM-700-EC Electro Chemical Universal ITM |
| 600-003215-000 | Splash guard adapter for DM/O2/PI |
| 377-242400-100 | Hydrogen Sulfide plug-in sensor for DM-700-H2S |
| 1.1.14 Spare Parts - DM-700-O2 Oxygen Deficiency Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-345500-025 | DM-700-O2 Oxygen Deficiency (ITM) |
| 600-003215-000 | Splash guard adapter for DM/O2/PI |
| 377-343400-025 | Oxygen plug-in sensor for DM-700-O2 |
| 1.1.15 Spare Parts - PI-700-VOC Volatile Organic Compound Sensor Assembly | |
| Part Number | Model Number - Description |
| 927-P25500-000 | PI-700 Volatile Organic Compound (ITM) Universal |
| 600-003215-000 | Splash guard adapter for DM/O2/PI |
| 377-P10000-010 | Photo Ionization plug-in sensor for PI-700-10 (0-10ppm) |
| 377-P20000-01K | Photo Ionization plug-in sensor for PI-701-1K (0-1000ppm) |
| 602-003295-FLT | PI-700 Splash guard adapter assembly with filter |
| 1.1.16 Spare Parts - IR-700-CO2 Infrared Sensor Assembly | |
| 927-405500-000 | IR-700-CO2 Infrared Carbn Dioxide ( ITM ) Low range ( 0-5%) |
| 927-425500-000 | IR-700-CO2 Infrared Carbn Dioxide ( ITM ) High range ( 10-100%) |
| 602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor |
| 370-365878-700 | Carbon Dioxide plug-in sensor for IR-700-CO2 (0-5%) |
| 370-287724-700 | Carbon Dioxide plug-in sensor for IR-700-CO2 (10-100%) |
| 1.1.17 Spare Parts - DM-700 Electrochemical Toxic Gas Sensor Assemblies | |
| Part Number | Model Number - Description |
| 927-245500-000 | DM-700-EC Electro Chemical Universal ITM |
| 600-003215-000 | Splash guard adapter for DM/O2/PI |
| 377-12EA01-100 | Acetyldehyde plug-in sensor for DM-700-C2H3O |
| 377-12EG01 -100 | Acetylene plug-in sensor for DM-700-C2H2 |
| 377-12EM01-100 | Acrylonitrile plug-in sensor for DM-700-C3H3N |
| 377-505001-100 | Ammonia plug-in sensor for DM-702-NH3 |
| 377-191901-001 | Arsine plug-in sensor for DM-700-AsH3 |
| 377-747501-005 | Bromine plug-in sensor for DM-700-Br2 |
| 377-12EB01-100 | Butadiene plug-in sensor for DM-700-C4H6 |
| 377-444401-100 | Carbon Monoxide plug-in sensor for DM-700-CO |
| 377-747401-010 | Chlorine plug-in sensor for DM-700-CL2 |
| 377-777701-001 | Chlorine Dioxide plug-in sensor for DM-700-CLO2 (0-1ppm) |
| 377-747601-050 | Chlorine Dioxide plug-in sensor for DM-700-CLO2 (0-50ppm) |
| 377-192101-005 | Diborane plug-in sensor for DM-700-B2H6 |
| 377-12EO01-100 | Ethanol plug-in sensor for DM-700-C2H5OH |
| 377-24EZ01-100 | Ethyl Mercaptan plug-in sensor for DM-700-C2H5SH |
| 377-12ED01-100 | Ethylene plug-in sensor for DM-700-C2H4 |
| 377-12EJ01-100 | Ethylene Oxide plug-in sensor for DM-700-C2H4O |
| 377-272701-001 | Fluorine plug-in sensor for DM-700-F2 |
| 377-12EP01-100 | Formaldehyde plug-in sensor for DM-700-CH2O |
| 377-232501-002 | Germane plug-in sensor for DM-700-GeH4 |
| 377-262601-001 | Hydrazine plug-in sensor for DM-700-N2H4 |
| 377-848401-100 | Hydrogen plug-in sensor for DM-700-H2 (ppm range) |
| 377-050501-04P | Hydrogen plug-in sensor for DM-700-H2 (1% & 4% range) |
| 377-090801-030 | Hydrogen Bromide plug-in sensor for DM-700-HBr |
| 377-090901-030 | Hydrogen Chloride plug-in sensor for DM-700-HCL |
| 377-131301-030 | Hydrogen Cyanide plug-in sensor for DM-700-HCN |
| 377-333301-010 | Hydrogen Fluoride plug-in sensor for DM-700-HF |
| 377-242401-100 | Hydrogen Sulfide plug-in sensor for DM-700-H2S |
| 377-12EE01-100 | Methanol plug-in sensor for DM-700-CH3OH |
| 377-12EK01-100 | Methyl Mercaptan plug-in sensor for DM-700-CH3SH |
| 377-949401-100 | Nitric Oxide plug-in sensor for DM-700-NO |
| 377-646401-010 | Nitrogen Dioxide plug-in sensor for DM-700-NO2 |
| 377-393901-001 | Ozone plug-in sensor for DM-700-O3 |
| 377-414101-001 | Phosgene plug-in sensor for DM-700-COCL2 |
| 377-192001-005 | Phosphine plug-in sensor for DM-700-PH3 |
| 377-232301-050 | Silane plug-in sensor for DM-700-SiH4 |
| 377-555501-020 | Sulfur Dioxide plug-in sensor for DM-700-SO2 |
| 377-12EF01-100 | Vinyl Acetate plug-in sensor for DM-700-C4H6O2 |
| 377-12EL01-100 | Vinyl Chloride plug-in sensor for DM-700-C2H3CL |
| Section 1.2 Model Series 600 MicroSafe Gas Detection Sensors | |
| 1.2.1 Combustible Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 966-524520-100 | FP-624C Catalytic Combustible Gas Sensor Assembly |
| 966-224520-100 | IR-622 Infrared Combustible Hydrocarbon Sensor Assembly |
| Standard range for IR combustible hydrocarbon is 100% LEL. Contact the Detcon factory for other ranges. | |
| 1.2.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 966-014520-100 | TP-624D Solid State MOS H2S Sensor Assembly |
| 966-01452B-100 | TP-624D-316SS Solid State MOS H2S Sensor Assembly |
| 966-242480-100 | DM-600IS-H2S Sensor Assembly |
| 1.2.3 Oxygen Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 966-344520-025 | DM-634 Oxygen Gas Sensor Assembly |
| 1.2.4 VOC Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 966-P14520-010 | PI-600-VOC Sensor Assembly 0-10 PPM |
| 966-P24520-01K | PI-601-VOC Sensor Assembly 0-1000 PPM |
| 1.2.5 Carbon Dioxide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 966-404520-005 | IR-640 Infrared Carbon Dioxide Sensor Assembly (range 0-5%) |
| 966-424520-100 | IR-642 Infrared Carbon Dioxide Sensor Assembly (range 10-100%) |
| Contact the Detcon factory for other ranges. | |
| 1.2.6 Electrochemical Toxic Gas Detection Sensor Assemblies | |
| Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | |
| Note: Detcon recommends selection of the 316SS J-box for strong acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | |
| Part Number | Model Number - Description |
| 966-12EA80-100 | DM-600IS-C2H3O Acetyldehyde Sensor Assembly |
| 966-12EG80-100 | DM-600IS-C2H2 Acetylene Sensor Assembly |
| 966-12EM80-100 | DM-600IS-C3H3N Acrylonitrile Sensor Assembly |
| 966-505080-100 | DM-602IS-NH3 Ammonia Sensor Assembly |
| 966-191980-001 | DM-600IS-AsH3 Arsine Sensor Assembly |
| 966-747580-005 | DM-600IS-Br2 Bromine Sensor Assembly |
| 966-12EB80-100 | DM-600IS-C4H6 Butadiene Sensor Assembly |
| 966-444480-100 | DM-600IS-CO Carbon Monoxide Sensor Assembly |
| 966-747480-010 | DM-600IS-CL2 Chlorine Sensor Assembly |
| 966-777780-001 | DM-601IS-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) |
| 966-747680-050 | DM-600IS-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) |
| 966-192180-005 | DM-600IS-B2H6 Diborane Sensor Assembly |
| 966-12EO80-100 | DM-600IS-C2H5OH Ethanol Sensor Assembly |
| 966-24EZ80-100 | DM-600IS-C2H5SH Ethyl Mercaptans Sensor Assembly |
| 966-12ED80-100 | DM-600IS-C2H4 Ethylene Sensor Assembly |
| 966-12EJ80-100 | DM-600IS-C2H4O Ethylene Oxide Sensor Assembly |
| 966-272780-001 | DM-600IS-F2 Fluorine Sensor Assembly |
| 966-12EP80-100 | DM-600IS-CH2O Formaldehyde Sensor Assembly |
| 966-232580-002 | DM-600IS-GeH4 Germane Sensor Assembly |
| 966-262680-001 | DM-600IS-N2H4 Hydrazine Sensor Assembly |
| 966-848480-100 | DM-600IS-H2 Hydrogen Sensor Assembly (ppm Range) |
| 966-050580-04P | DM-601IS-H2 Hydrogen Sensor Assembly (% Range) |
| 966-070780-01P | DM-602IS-H2 Hydrogen Sensor Assembly (1% Range) |
| 966-090880-030 | DM-600IS-HBr Hydrogen Bromide Sensor Assembly |
| 966-090980-030 | DM-600IS-HCL Hydrogen Chloride Sensor Assembly |
| 966-131380-030 | DM-600IS-HCN Hydrogen Cyanide Sensor Assembly |
| 966-333380-010 | DM-600IS-HF Hydrogen Fluoride Sensor Assembly |
| 966-242480-100 | DM-600IS-H2S Hydrogen Sulfide Sensor Assembly |
| 966-12EE80-100 | DM-600IS-CH3OH Methanol Sensor Assembly |
| 966-24EK80-100 | DM-600IS-CH3SH Methyl Mercaptans Sensor Assembly |
| 966-949480-100 | DM-600IS-NO Nitric Oxide Sensor Assembly |
| 966-646480-010 | DM-600IS-NO2 Nitrogen Dioxide Sensor Assembly |
| 966-393980-001 | DM-600IS-O3 Ozone Sensor Assembly |
| 966-414180-001 | DM-600IS-COCL2 Phosgene Sensor Assembly |
| 966-192080-005 | DM-600IS-PH3 Phosphine Sensor Assembly |
| 966-232380-050 | DM-600IS-SiH4 Silane Sensor Assembly |
| 966-555580-020 | DM-600IS-SO2 Sulfur Dioxide Sensor Assembly |
| 966-12EF80-100 | DM-600IS-C4H6O2 Vinyl Acetate Sensor Assembly |
| 966-12EL80-100 | DM-600IS-C2H3CL Vinyl Chloride Sensor Assembly |
| 1.2.7 Model Series 600 Spare Parts - Universal | |
| Part Number | Model Number - Description |
| 327-000000-000 | Magnetic programming tool |
| 960-202200-000 | Condensation prevention packet (for J-Box replace annually) |
| 437-500000-000 | Stainless steel tag |
| 943-004223-000 | 2" pipe mount with sun shade |
| 943-004221-000 | Sensor Mounting Plate for 2" pipe |
| 975-225007-006 | Remote sensor Jbox, aluminum, 6 wire terminal strip |
| 975-316007-006 | Remote sensor Jbox, 316 stainless steel, 6 wire terminal strip |
| 897-850000-010 | Standard aluminum junction box with solid lid |
| 897-850901-010 | Standard aluminum junction box with lens cover |
| 897-850000-316 | Standard 316SS junction box with solid lid |
| 897-850901-316 | Standard 316SS junction box with lens cover |
| 943-003436-000 | Harsh location water guard |
| 943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard |
| 1.2.8 Spare Parts - FP-624C Catalytic Combustible Gas Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-201600-000 | Combustible gas field replaceable plug-in sensor |
| 926-525500-100 | Plug-in transmitter module (Model FP-624C) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 612-820000-000 | Stainless steel LEL sensor housing with threaded insert |
| 399-602016-000 | Stainless steel LEL sensor housings including plug-in sensor |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSFP00-624 | FP-624 remote sensor separation kit |
| 975-000020-890 | Sensor Duct Mount Kit LEL |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.9 Spare Parts - IR-622-CH Infrared Combustible Hydrocarbon Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-365871-212 | Combustible Hydrocarbon plug-in optical sensor for CH’s |
| 926-225500-100 | Plug-in transmitter control module (Model IR-622) |
| 500-002042-000 | Standard connector board Model series 600 IR sensors |
| 390-000087-000 | Stainless steel sensor housing assembly CH’s |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSIR00-622 | IR-622 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.10 Spare Parts - TP-624D Solid State MOS H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 399-800000-000 | Solid State MOS H2S Sensor in Stainless Steel Housing |
| 926-0155D0-100 | Plug-in transmitter control module (Model TP-624D) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 600-610000-000 | Sensor splash guard w/integral cal port TP-424/TP-524/TP-624 |
| 943-000006-038 | Calibration adapter TP |
| 326-000000-000 | Replaceable sintered stainless steel flame arrestor |
| 975-RSTP00-624 | TP-624 remote sensor separation kit |
| 975-000020-891 | Sensor Duct Mount Kit TP |
| 943-002274-000 | Harsh location dust guard (fits 7/8 x 14 thread) |
| 033-003236-000 | Harsh location dust guard replacement filter |
| 1.2.11 Spare Parts - DM-600-H2S Electro Chemical H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 394-242400-xxx* | Intrinsically Safe sensor housing w/preamp circuit *Specify range |
| 926-995580-000 | Universal plug-in transmitter control module (DM-600IS) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 613-002646-000 | Sensor splash guard with twist lock adapter |
| 975-RSDM00-600 | DM-600 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 370-242400-000 | Hydrogen Sulfide plug-in detector assembly |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.12 Spare Parts - DM-600-O2 Oxygen Deficiency Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-399100-000 | Oxygen field replaceable plug-in sensor 400/500/600 series |
| 926-345500-025 | Plug-in transmitter control module (Model DM-634) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 399-200000-000 | Stainless steel sensor housing with insert and flame arrestor |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 330-X50000-000 | Field Replaceable sintered stainless steel flame arrestor |
| 975-RSDM00-634 | DM-634 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.13 Spare Parts - PI-600-VOC Volatile Organic Compound Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-P10000-000 | Photo Ionization field replaceable plug-in detector 0-10 PPM |
| 370-P20000-000 | Photo Ionization field replaceable plug-in detector 0-1000 PPM |
| 926-P16480-010 | Plug-in transmitter control module (Model PI-600/PI-601) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 390-404142-010 | PID sensor housing assembly 10 ppm |
| 390-404142-01K | PID sensor housing assembly 1000 ppm |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 330-X50000-000 | Field replaceable sintered stainless steel flame arrestor |
| 975-600020-000 | PID 10.6eV replacement lamp |
| 975-600100-000 | PID detector replacement cell |
| 975-520040-000 | PID lamp cleaning kit |
| 975-RSPI00-600 | PI-600 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.14 Spare Parts - IR-640-CO2 Infrared Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-365878-111 | Carbon Dioxide plug-in optical sensor (up to 5% range) |
| 370-287724-232 | Carbon Dioxide plug-in optical sensor (10 to 100% range) |
| 926-405500-003 | Plug-in transmitter control module (Model IR-640) |
| 500-002042-000 | Standard connector board Model series 600 IR sensors |
| 390-000088-000 | Stainless steel sensor housing assembly CO2 |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 330-X50000-000 | Field replaceable sintered stainless steel flame arrestor |
| 975-RSIR00-640 | IR-640 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.2.15 Spare Parts - DM-600 Electrochemical Toxic Gas Sensor Assemblies | |
| Part Number | Model Number - Description |
| 926-995580-000 | Universal plug-in transmitter control module (DM-600IS) |
| 500-001794-004 | Standard connector board Model series 600 sensors |
| 394-xxxx00-xxx* | Intrinsically Safe sensor housing with pre-preamp circuit *Specify |
| gas type and range | |
| 613-002646-000 | Sensor splash guard with twist lock adapter |
| 975-RSDM00-600 | DM-600 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| * To specify gas type (digits 4 through 7 of the part number) refer to section | |
| 1.2.16, select the gas type then use digits 4 through 7 of the replacement | |
| sensor part number. To specify range of detection, reference the table | |
| below. For example, 100 ppm H2S would be 394-242400-100 | |
| *RANGE TABLE | |
| If greater than 999ppm, use a “K” (for 1000) | |
| If greater than 9,900ppm use a “P” (for %) | |
| Build range number from the right and use zeros to the left for blanks. | |
| 001 – 1 ppm | |
| 005 – 5 ppm | |
| 010 – 10 ppm | |
| 020 – 20 ppm | |
| 025 – 25 ppm | |
| 050 – 50 ppm | |
| 100 – 100 ppm | |
| 500 – 500 ppm | |
| 01K – 1000 ppm | |
| 05K – 5000 ppm | |
| 01P – 1 % | |
| 04P – 4 % | |
| 25P– 25 % | |
| 1.2.16 Spare Parts - DM-600 Replacement Electrochemical Sensor Cells | |
| DM-500, and DM-600 Series sensors | |
| Part Number | Model Number - Description |
| 370-12EA00-000 | Acetyldehyde plug-in detector assembly |
| 370-12EG00-000 | Acetylene plug-in detector assembly |
| 370-12EM00-000 | Acrylonitrile plug-in detector assembly |
| 370-505000-000 | Ammonia plug-indetector assembly |
| 370-191900-000 | Arsine plug-in detector assembly |
| 370-747500-000 | Bromine plug-in detector assembly |
| 370-12EB00-000 | Butadiene plug-in detector assembly |
| 370-444400-000 | Carbon Monoxide plug-in detector assembly |
| 370-747400-000 | Chlorine plug-in detector assembly |
| 370-777700-000 | Chlorine Dioxide plug-in detector assembly (0-1 PPM) |
| 370-747600-000 | Chlorine Dioxide plug-in detector assembly (0-50 PPM) |
| 370-192100-000 | Diborane plug-in detector assembly |
| 370-12EO00-000 | Ethanol plug-in detector assembly |
| 370-24EZ00-000 | Ethyl Mercaptan plug-in detector assembly |
| 370-12ED00-000 | Ethylene plug-in detector assembly |
| 370-12EJ00-000 | Ethylene Oxide plug-in detector assembly |
| 370-272700-000 | Fluorine plug-in detector assembly |
| 370-12EP00-000 | Formaldehyde plug-in detector assembly |
| 370-232500-000 | Germane plug-in detector assembly |
| 370-262600-000 | Hydrazine plug-in detector assembly |
| 370-848400-000 | Hydrogen PPM Range plug-in detector assembly |
| 370-050500-000 | Hydrogen LEL Range (1% and 4%) plug-in detector assy. |
| 370-090800-000 | Hydrogen Bromide plug-in detector assembly |
| 370-090900-000 | Hydrogen Chloride plug-in detector assembly |
| 370-131300-000 | Hydrogen Cyanide plug-in detector assembly |
| 370-333300-000 | Hydrogen Fluoride plug-in detector assembly |
| 370-242400-000 | Hydrogen Sulfide plug-in detector assembly |
| 370-12EE00-000 | Methanol plug-in detector assembly |
| 370-12EK00-000 | Methyl Mercaptan plug-in detector assembly |
| 370-949400-000 | Nitric Oxide plug-in detector assembly |
| 370-646400-000 | Nitrogen Dioxide plug-in detector assembly |
| 370-393900-000 | Ozone plug-in detector assembly |
| 370-414100-000 | Phosgene plug-in detector assembly |
| 370-192000-000 | Phosphine plug-in detector assembly |
| 370-232300-000 | Silane plug-in detector assembly |
| 370-555500-000 | Sulfur Dioxide plug-in detector assembly |
| 370-12EF00-000 | Vinyl Acetate plug-in detector assembly |
| 370-12EL00-000 | Vinyl Chloride plug-in detector assembly |
| Section 1.3 Model Series 500 MicroSafe Gas Detection Sensors | |
| 1.3.1 Combustible Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 965-525420-100 | FP-524C Catalytic Combustible Gas Sensor Assembly |
| 965-225420-100 | IR-522 Infrared Combustible Hydrocarbon Sensor Assembly |
| Standard range for IR combustible hydrocarbon is 100% LEL. Contact the Detcon factory for other ranges. | |
| 1.3.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 965-015420-100 | TP-524D Solid State MOS H2S Sensor Assembly |
| 965-01542B-100 | TP-524D-316SS Solid State MOS H2S Sensor Assembly |
| 965-242480-100 | DM-500IS-H2S Sensor Assembly |
| 1.3.3 Oxygen Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 965-345420-025 | DM-534 Oxygen Gas Sensor Assembly |
| 1.3.4 VOC Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 965-P15420-010 | PI-500-VOC Sensor Assembly 0-10 PPM |
| 965-P25420-01K | PI-501-VOC Sensor Assembly 0-1000 PPM |
| 1.3.5 Carbon Dioxide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 965-405420-005 | IR-540 Infrared Carbon Dioxide Sensor Assembly (range 0-5%) |
| 965-425420-100 | IR-542 Infrared Carbon Dioxide Sensor Assembly (range 10-100%) |
| Contact the Detcon factory for other ranges. | |
| 1.3.6 Electrochemical Toxic Gas Detection Sensor Assemblies | |
| Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | |
| Note: Detcon recommends selection of the 316SS J-box for strong acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | |
| Part Number | Model Number - Description |
| 965-12EA80-100 | DM-500IS-C2H3O Acetyldehyde Sensor Assembly |
| 965-12EG80-100 | DM-500IS-C2H2 Acetylene Sensor Assembly |
| 965-12EM80-100 | DM-500IS-C3H3N Acrylonitrile Sensor Assembly |
| 965-505080-100 | DM-502IS-NH3 Ammonia Sensor Assembly |
| 965-191980-001 | DM-500IS-AsH3 Arsine Sensor Assembly |
| 965-747580-005 | DM-500IS-Br2 Bromine Sensor Assembly |
| 965-12EB80-100 | DM-500IS-C4H6 Butadiene Sensor Assembly |
| 965-444480-100 | DM-500IS-CO Carbon Monoxide Sensor Assembly |
| 965-747480-010 | DM-500IS-CL2 Chlorine Sensor Assembly |
| 965-777780-001 | DM-501IS-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) |
| 965-747680-050 | DM-500IS-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) |
| 965-192180-005 | DM-500IS-B2H6 Diborane Sensor Assembly |
| 965-12EO80-100 | DM-500IS-C2H5OH Ethanol Sensor Assembly |
| 965-24EZ80-100 | DM-500IS-C2H5SH Ethyl Mercaptans Sensor Assembly |
| 965-12ED80-100 | DM-500IS-C2H4 Ethylene Sensor Assembly |
| 965-12EJ80-100 | DM-500IS-C2H4O Ethylene Oxide Sensor Assembly |
| 965-272780-001 | DM-500IS-F2 Fluorine Sensor Assembly |
| 965-12EP80-100 | DM-500IS-CH2O Formaldehyde Sensor Assembly |
| 965-232580-002 | DM-500IS-GeH4 Germane Sensor Assembly |
| 965-262680-001 | DM-500IS-N2H4 Hydrazine Sensor Assembly |
| 965-848480-100 | DM-500IS-H2 Hydrogen Sensor Assembly (ppm Range) |
| 965-050580-04P | DM-501IS-H2 Hydrogen Sensor Assembly (% Range) |
| 965-070780-01P | DM-502IS-H2 Hydrogen Sensor Assembly (1% Range) |
| 965-090880-030 | DM-500IS-HBr Hydrogen Bromide Sensor Assembly |
| 965-090980-030 | DM-500IS-HCL Hydrogen Chloride Sensor Assembly |
| 965-131380-030 | DM-500IS-HCN Hydrogen Cyanide Sensor Assembly |
| 965-333380-010 | DM-500IS-HF Hydrogen Fluoride Sensor Assembly |
| 965-242480-100 | DM-500IS-H2S Hydrogen Sulfide Sensor Assembly |
| 965-12EE80-100 | DM-500IS-CH3OH Methanol Sensor Assembly |
| 965-24EK80-100 | DM-500IS-CH3SH Methyl Mercaptans Sensor Assembly |
| 965-949480-100 | DM-500IS-NO Nitric Oxide Sensor Assembly |
| 965-646480-010 | DM-500IS-NO2 Nitrogen Dioxide Sensor Assembly |
| 965-393980-001 | DM-500IS-O3 Ozone Sensor Assembly |
| 965-414180-001 | DM-500IS-COCL2 Phosgene Sensor Assembly |
| 965-192080-005 | DM-500IS-PH3 Phosphine Sensor Assembly |
| 965-232380-050 | DM-500IS-SiH4 Silane Sensor Assembly |
| 965-555580-020 | DM-500IS-SO2 Sulfur Dioxide Sensor Assembly |
| 965-12EF80-100 | DM-500IS-C4H6O2 Vinyl Acetate Sensor Assembly |
| 965-12EL80-100 | DM-500IS-C2H3CL Vinyl Chloride Sensor Assembly |
| 1.3.7 Model Series 500 Spare Parts - Universal | |
| Part Number | Model Number - Description |
| 327-000000-000 | Magnetic programming tool |
| 960-202200-000 | Condensation prevention packet (for J-Box replace annually) |
| 437-500000-000 | Stainless steel tag |
| 943-004223-000 | 2" pipe mount with sun shade |
| 943-004221-000 | Sensor Mounting Plate for 2" pipe |
| 975-225007-006 | Remote sensor Jbox, aluminum, 6 wire terminal strip |
| 975-316007-006 | Remote sensor Jbox, 316 stainless steel, 6 wire terminal strip |
| 897-850000-010 | Standard aluminum junction box with solid lid |
| 897-850901-010 | Standard aluminum junction box with lens cover |
| 897-850000-316 | Standard 316SS junction box with solid lid |
| 897-850901-316 | Standard 316SS junction box with lens cover |
| 943-003436-000 | Harsh location water guard |
| 943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard |
| 1.3.8 Spare Parts - FP-524C Catalytic Combustible Gas Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-201600-000 | Combustible gas field replaceable plug-in sensor |
| 399-602016-000 | Stainless steel LEL sensor housings including plug-in sensor |
| 925-525400-100 | Plug-in transmitter module (Model FP-524C) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 612-820000-000 | Stainless steel LEL sensor housing with threaded insert |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSFP00-524 | FP-524 remote sensor separation kit |
| 975-000020-890 | Sensor Duct Mount Kit LEL |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.9 Spare Parts - IR-522-CH Infrared Combustible Hydrocarbon Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-365871-212 | Combustible Hydrocarbon plug-in optical sensor for CH’s |
| 925-225400-100 | Plug-in transmitter control module (Model IR-522) |
| 500-002226-001 | Standard connector board Model series 500 IR sensors |
| 390-000087-000 | Stainless steel sensor housing assembly CH’s |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSIR00-522 | IR-522 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.10 Spare Parts - TP-524D Solid State MOS H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 399-800000-000 | Solid State MOS H2S Sensor in Stainless Steel Housing |
| 925-0154D0-100 | Plug-in transmitter control module (Model TP-524D) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 326-000000-000 | Replaceable sintered stainless steel flame arrestor |
| 600-610000-000 | Sensor splash guard w/integral cal port TP-424/TP-524/TP-624 |
| 943-000006-038 | Calibration adapter TP |
| 975-RSTP00-524 | TP-524 remote sensor separation kit |
| 975-000020-891 | Sensor Duct Mount Kit TP |
| 943-002274-000 | Harsh location dust guard (fits 7/8 x 14 thread) |
| 033-003236-000 | Harsh location dust guard replacement filter |
| 1.3.11 Spare Parts - DM-500-H2S Electro Chemical H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 925-995480-000 | Universal plug-in transmitter control module (DM-500IS) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 394-242400-xxx* | Intrinsically Safe sensor housing with pre-preamp circuit *Specify |
| range | |
| 613-002646-000 | Sensor splash guard with twist lock adapter |
| 975-RSDM00-500 | DM-500 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 370-242400-000 | Hydrogen Sulfide plug-in detector assembly |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.12 Spare Parts - DM-500-O2 Oxygen Deficiency Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-399100-000 | Oxygen field replaceable plug-in sensor 400/500/600 series |
| 925-345400-025 | Plug-in transmitter control module (Model DM-534) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 399-200000-000 | Stainless steel sensor housing with insert and flame arrestor |
| 330-X50000-000 | Field Replaceable sintered stainless steel flame arrestor |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSDM00-534 | DM-534 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.13 Spare Parts - PI-500-VOC Volatile Organic Compound Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-P10000-000 | Photo Ionization field replaceable plug-in detector 0-10 PPM |
| 370-P20000-000 | Photo Ionization field replaceable plug-in detector 0-1000 PPM |
| 925-P15480-010 | Plug-in transmitter control module (Model PI-500/PI-501) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 390-404142-010 | PID sensor housing assembly 10 ppm |
| 390-404142-01K | PID sensor housing assembly 1000 ppm |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 330-X50000-000 | Field replaceable sintered stainless steel flame arrestor |
| 975-600020-000 | PID 10.6eV replacement lamp |
| 975-600100-000 | PID detector replacement cell |
| 975-520040-000 | PID lamp cleaning kit |
| 975-RSPI00-500 | PI-500 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.14 Spare Parts - IR-540-CO2 Infrared Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-365878-111 | Carbon Dioxide plug-in optical sensor (up to 5% range) |
| 370-287724-232 | Carbon Dioxide plug-in optical sensor (10 to 100% range) |
| 925-405400-003 | Plug-in transmitter control module (Model IR-540) |
| 500-002226-001 | Standard connector board Model series 500 IR sensors |
| 390-000088-000 | Stainless steel sensor housing assembly CO2 |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSIR00-540 | IR-540 remote sensor separation kit |
| 975-000208-9IR | Sensor Duct Mount Kit IR |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.3.15 Spare Parts - DM-500 Electrochemical Toxic Gas Sensor Assemblies | |
| Part Number | Model Number - Description |
| 925-995480-000 | Universal plug-in transmitter control module (DM-500IS) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 394-xxxx00-xxx* | Intrinsically Safe sensor housing with pre-preamp circuit *Specify |
| gas type and range | |
| 613-002646-000 | Sensor splash guard with twist lock adapter |
| 975-RSDM00-500 | DM-500 remote sensor separation kit |
| 975-000020-892 | Sensor Duct Mount Kit – DM Series |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| * To specify gas type (digits 4 through 7 of the part number) refer to section | |
| 1.3.16, select the gas type then use digits 4 through 7 of the replacement | |
| sensor part number. To specify range of detection, reference the table | |
| below. For example, 100 ppm H2S would be 394-242400-100 | |
| *RANGE TABLE | |
| If greater than 999ppm, use a “K” (for 1000) | |
| If greater than 9,900ppm use a “P” (for %) | |
| Build range number from the right and use zeros to the left for blanks. | |
| 001 – 1 ppm | |
| 005 – 5 ppm | |
| 010 – 10 ppm | |
| 020 – 20 ppm | |
| 025 – 25 ppm | |
| 050 – 50 ppm | |
| 100 – 100 ppm | |
| 500 – 500 ppm | |
| 01K – 1000 ppm | |
| 05K – 5000 ppm | |
| 01P – 1 % | |
| 04P – 4 % | |
| 25P– 25 % | |
| 1.3.16 Spare Parts - DM-500 Replacement Electrochemical Sensor Cells | |
| Part Number | Model Number - Description |
| Reference section 1.2.16 for Replacement Electrochemical Sensor Cells | |
| Section 1.4 Model Series 400 Gas Detection Sensors | |
| 1.4.1 Combustible Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 964-525420-100 | FP-424C Catalytic Combustible Gas Sensor Assembly |
| 1.4.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | |
| Part Number | Model Number - Description |
| 964-015420-100 | TP-424C Solid State MOS H2S Sensor Assembly |
| 1.4.3 Model Series 400 Spare Parts - Universal | |
| Part Number | Model Number - Description |
| 960-202200-000 | Condensation prevention packet (for J-Box replace annually) |
| 437-500000-000 | Stainless steel tag |
| 943-004223-000 | 2" pipe mount with sun shade |
| 943-004221-000 | Sensor Mounting Plate for 2" pipe |
| 975-225007-006 | Remote sensor Jbox, aluminum, 6 wire terminal strip |
| 975-316007-006 | Remote sensor Jbox, 316 stainless steel, 6 wire terminal strip |
| 897-850000-010 | Standard aluminum junction box with solid lid |
| 897-850901-010 | Standard aluminum junction box with lens cover |
| 897-850000-316 | Standard 316SS junction box with solid lid |
| 897-850901-316 | Standard 316SS junction box with lens cover |
| 943-000000-000943-003436-000 | CalibrationHarsh locationSleeve/Windwater guardGuard for use with splash guard |
| 1.4.4 Spare Parts - FP-424C Catalytic Combustible Gas Sensor Assembly | |
| Part Number | Model Number - Description |
| 370-201600-000 | Combustible gas field replaceable plug-in sensor |
| 612-820000-000 | Stainless steel LEL sensor housing with threaded insert |
| 399-602016-000 | Stainless steel LEL sensor housings including plug-in sensor |
| 924-525400-100 | Plug-in transmitter module (Model FP-424C) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR |
| 943-000006-132 | Calibration adapter FP/IR/DM/O2 |
| 975-RSFP00-424 | FP-424 remote sensor separation kit |
| 975-000020-890 | Sensor Duct Mount Kit LEL |
| 612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR |
| 033-003238-000943-002273-000 | HarshHarsh locationlocation dustdust guardguard replacement(fits 1.5 x 18 thread)filter |
| 1.4.5 Spare Parts - TP-424C Solid State MOS H2S Sensor Assembly | |
| Part Number | Model Number - Description |
| 399-800000-000 | Solid State MOS H2S Sensor in Stainless Steel Housing |
| 924-015400-100 | Plug-in transmitter control module ( Model TP-424) |
| 500-005065-007 | Standard connector board Model series 400 & 500 sensors |
| 600-610000-000 | Sensor splash guard w/integral cal port TP-424/TP-524/TP-624 |
| 943-002274-000 | Calibration adapter TP |
| 326-000000-000 | Replaceable sintered stainless steel flame arrestor |
| 975-RSTP00-424 | TP-424 Remote Sensor separation kit |
| 975-000020-891 | Sensor Duct Mount Kit TP |
| 943-000006-038 | Harsh location dust guard ( fits 7/8 x 14 thread ) |
| 033-003236-000 | Harsh location dust guard replacement filter |
| Section 1.5 Model Series 100 Low Power Gas Detection Sensors | |
| (Does not include junction box or loop-powered display. See section 1.5.2 for junction box & | |
| display adder instructions.) | |
| 1.5.1 Electrochemical Toxic Gas Detection Sensor Assemblies | |
| Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | |
| Part Number | Model Number - Description |
| 961-EA0025-100 | DM-100-C2H3O Acetyldehyde Sensor Assembly |
| 961-EG0025-100 | DM-100-C2H2 Acetylene Sensor Assembly |
| 961-EM0025-100 | DM-100-C3H3N Acrylonitrile Sensor Assembly |
| 961-500025-100 | DM-102-NH3 Ammonia Sensor Assembly |
| 961-190025-001 | DM-100-AsH3 Arsine Sensor Assembly |
| 961-750025-005 | DM-100-Br2 Bromine Sensor Assembly |
| 961-EB0025-100 | DM-100-C4H6 Butadiene Sensor Assembly |
| 961-440025-100 | DM-100-CO Carbon Monoxide Sensor Assembly |
| 961-740025-010 | DM-100-CL2 Chlorine Sensor Assembly |
| 961-770025-001 | DM-101-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) |
| 961-760025-050 | DM-100-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) |
| 961-210025-005 | DM-100-B2H6 Diborane Sensor Assembly |
| 961-EO0025-100 | DM-100-C2H5OH Ethanol Sensor Assembly |
| 961-EZ0025-100 | DM-100-C2H5SH Ethyl Mercaptans Sensor Assembly |
| 961-ED0025-100 | DM-100-C2H4 Ethylene Sensor Assembly |
| 961-EJ0025-100 | DM-100-C2H4O Ethylene Oxide Sensor Assembly |
| 961-270025-001 | DM-100-F2 Fluorine Sensor Assembly |
| 961-EP0025-100 | DM-100-CH2O Formaldehyde Sensor Assembly |
| 961-250025-002 | DM-100-GeH4 Germane Sensor Assembly |
| 961-260025-001 | DM-100-N2H4 Hydrazine Sensor Assembly |
| 961-840025-100 | DM-100-H2 Hydrogen Sensor Assembly (ppm Range) |
| 961-050025-04P | DM-101-H2 Hydrogen Sensor Assembly (4% Range) |
| 961-070025-01P | DM-102-H2 Hydrogen Sensor Assembly (1% Range) |
| 961-080025-030 | DM-100-HBr Hydrogen Bromide Sensor Assembly |
| 961-090025-030 | DM-100-HCL Hydrogen Chloride Sensor Assembly |
| 961-130025-030 | DM-100-HCN Hydrogen Cyanide Sensor Assembly |
| 961-330025-010 | DM-100-HF Hydrogen Fluoride Sensor Assembly |
| 961-240025-100 | DM-100-H2S Hydrogen Sulfide Sensor Assembly |
| 961-EE0025-100 | DM-100-CH3OH Methanol Sensor Assembly |
| 961-EK0025-100 | DM-100-CH3SH Methyl Mercaptans Sensor Assembly |
| 961-940025-100 | DM-100-NO Nitric Oxide Sensor Assembly |
| 961-640025-010 | DM-100-NO2 Nitrogen Dioxide Sensor Assembly |
| 961-340025-25P | DM-100-O2 Oxygen Deficiency Sensor Assembly |
| 961-390025-001 | DM-100-O3 Ozone Sensor Assembly |
| 961-410025-001 | DM-100-COCL2 Phosgene Sensor Assembly |
| 961-200025-005 | DM-100-PH3 Phosphine Sensor Assembly |
| 961-230025-050 | DM-100-SiH4 Silane Sensor Assembly |
| 961-550025-020 | DM-100-SO2 Sulfur Dioxide Sensor Assembly |
| 961-EF0025-100 | DM-100-C4H6O2 Vinyl Acetate Sensor Assembly |
| 961-EL0025-100 | DM-100-C2H3CL Vinyl Chloride Sensor Assembly |
| 1.5.2 Model Series 100 Junction Box & Loop-Powered Display Adder | |
| Part Number | |
| Electrochemical: NOTE: Detcon recommends selection of the 316SS J-box for strong | |
| acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | |
| With aluminum junction box, indicate a "1" in position 9 of the PN (xxx-xxxxx1-xxx) | |
| With 316 stainless steel junction box, indicate a "3" in position 9 of the PN (xxx-xxxxx3-xxx) | |
| With aluminum junction box and loop-powered display, indicate a "2" in position 9 of the PN (xxx-xxxxx2-xxx) | |
| With 316SS junction box and loop-powered display, indicate a "4" in position 9 of the PN (xxx-xxxxx4-xxx) | |
| 1.5.3 Model Series 100 Accessories | |
| Part Number | |
| Transient Protection Module | |
| Alarm Relay Board | |
| Current to RS-485 Converter | |
| Loop Powered LED Display | |
| 1.5.4 Model Series 100 Spare Parts - Universal | |
| Part Number | |
| 613-120000-700 | Sensor splash guard with integral cal-port |
| 327-000000-000 | Magnetic programming tool |
| Sensor duct mount kit – 100 Series | |
| 960-202200-000 | Condensation prevention packet (for J-Box replace annually) |
| Loop-powered display assembly | |
| 437-500000-000 | Stainless steel tag |
| 943-004223-000 | 2" pipe mount with sun shade |
| 943-004221-000 | Sensor Mounting Plate for 2" pipe |
| 897-850000-010 | Standard aluminum junction box with solid lid |
| 897-850901-010 | Standard aluminum junction box with lens cover |
| 897-850000-316 | Stainless steel junction box with solid cover |
| 897-850901-316 | Stainless steel junction box with lens cover |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 943-003436-000 | Harsh location water guard |
| 943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard |
| 943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) |
| 033-003238-000 | Harsh location dust guard replacement filter |
| 1.5.5 Spare Parts - DM-100 Replacement Electrochemical Sensor Cells | |
| Part Number | Model Number - Description |
| DM-100 Electro Chemical Universal ITM | |
| 371-12EA00-100 | Acetyldehyde plug-in sensor for DM-100-C2H3O |
| 371-12EG00-100 | Acetylene plug-in sensor for DM-100-C2H2 |
| 371-12EM00-100 | Acrylonitrile plug-in sensor for DM-100-C3H3N |
| 371-505000-100 | Ammonia plug-in sensor for DM-102-NH3 |
| 371-191900-001 | Arsine plug-in sensor for DM-100-AsH3 |
| 371-747500-005 | Bromine plug-in sensor for DM-100-Br2 |
| 371-12EB00-100 | Butadiene plug-in sensor for DM-100-C4H6 |
| 371-444400-100 | Carbon Monoxide plug-in sensor for DM-100-CO |
| 371-747400-010 | Chlorine plug-in sensor for DM-100-CL2 |
| 371-777700-001 | Chlorine Dioxide plug-in sensor for DM-100-CLO2 (0-1ppm) |
| 371-282800-050 | Chlorine Dioxide plug-in sensor for DM-100-CLO2 (0-50ppm) |
| 371-192100-005 | Diborane plug-in sensor for DM-100-B2H6 |
| 371-12EO00-100 | Ethanol plug-in sensor for DM-100-C2H5OH |
| 371-24EZ00-100 | Ethyl Mercaptan plug-in sensor for DM-100-C2H5SH |
| 371-12ED00-100 | Ethylene plug-in sensor for DM-100-C2H4 |
| 371-12EJ00-100 | Ethylene Oxide plug-in sensor for DM-100-C2H4O |
| 371-272700-001 | Fluorine plug-in sensor for DM-100-F2 |
| 371-12EP00-100 | Formaldehyde plug-in sensor for DM-100-CH2O |
| 371-232500-002 | Germane plug-in sensor for DM-100-GeH4 |
| 371-262600-001 | Hydrazine plug-in sensor for DM-100-N2H4 |
| 371-848400-100 | Hydrogen plug-in sensor for DM-100-H2 (ppm range) |
| 371-050500-04P | Hydrogen plug-in sensor for DM-100-H2 (1% & 4% range) |
| 371-090800-030 | Hydrogen Bromide plug-in sensor for DM-100-HBr |
| 371-090900-030 | Hydrogen Chloride plug-in sensor for DM-100-HCL |
| 371-131300-030 | Hydrogen Cyanide plug-in sensor for DM-100-HCN |
| 371-333300-010 | Hydrogen Fluoride plug-in sensor for DM-100-HF |
| 371-242400-100 | Hydrogen Sulfide plug-in sensor for DM-100-H2S |
| 371-12EE00-100 | Methanol plug-in sensor for DM-100-CH3OH |
| 371-24EK00-100 | Methyl Mercaptan plug-in sensor for DM-100-CH3SH |
| 371-949400-100 | Nitric Oxide plug-in sensor for DM-100-NO |
| 371-646400-010 | Nitrogen Dioxide plug-in sensor for DM-100-NO2 |
| 371-343400-025 | Oxygen Deficiency sensor for DM-100-O2 |
| 371-999900-001 | Ozone plug-in sensor for DM-100-O3 |
| 371-414100-001 | Phosgene plug-in sensor for DM-100-COCL2 |
| 371-192000-005 | Phosphine plug-in sensor for DM-100-PH3 |
| 371-232300-050 | Silane plug-in sensor for DM-100-SiH4 |
| 371-555500-020 | Sulfur Dioxide plug-in sensor for DM-100-SO2 |
| 371-12EF00-100 | Vinyl Acetate plug-in sensor for DM-100-C4H6O2 |
| 371-12EL00-100 | Vinyl Chloride plug-in sensor for DM-100-C2H3CL |
Thứ Năm, 3 tháng 12, 2015
Hydrogen Chloride plug-in sensor for DM-100-HCL
Đăng ký:
Đăng Nhận xét (Atom)
Hỗ trợ trực tuyến
Nguyễn Thị Xuân Đào - Sales Engineer
Chào mừng quý khách đã đến với tự động hóa
.
Hãy liên hệ ngay với chúng tôi để được hỗ trợ giá tốt nhất
email: kendy0209@gmail.com
Hotline: 0989.073.182 Skype: mskendy
email: kendy0209@gmail.com
Hotline: 0989.073.182 Skype: mskendy
Không có nhận xét nào:
Đăng nhận xét