KRACHT
|
P.0190100001
Screw Type Flow Meter SVC 40 A1 G1 F1 S1
Materials
Material housing Spheroidal cast iron EN-GJS 400
Material Measuring unit Heat-treated steel
Material O-rings FKM
Bearing Ball bearing
Product data
Pulse volume 5.130 cm³/pulse
Type of connection pipe connection G 1 1/2"
Electronic output 2 squarewave signals, 90° shifted
Electrical connection Rectangular connector - Terminal strip
Standard temperature execution
Supply voltage 24 V DC (12...30 V DC)
Specific data
Measuring range 4...600 l/min
Starting point at 0.1 l/min
Measuring accuracy +/- 0.2% of reading (at viscosity: min. 20
mm²/s)
Linearity +/- 0.1%
Resolution 194.9 pulses/l (Evaluation of one measuring channel)
389.8 pulses/l (Evaluation of both measuring channels)
779.7 pulses/l (4-fold evaluation)
max. operating pressure 250 bar
Fluid temperature -15°C...+120°C
Ambient temperature -15°C...+80°C
max. perm. foreign particle 400 µm
|
KRACHT
|
P.0198810001
Gear Type Flow Meter VCA 5 FE R1 /176
Materials
Material housing Aluminium AlMgSi F30
Material Measuring unit Steel 1.7139
Material O-rings FKM
Bearing Ball bearing
Product data
Pulse volume 5.222 cm³/pulse
Type of connection Pipe connection G1"
Electronic output 1 square wave signal
Electrical connection Rectangular connector - Terminal strip
Standard temperature execution
Supply voltage 24 V DC (12...30 V DC)
Specific data
Measuring range 1...200 l/min
Starting point at 0.1 l/min
Measuring accuracy +/- 1% of reading (at viscosity: min. 20
mm²/s)
Linearity +/- 0.1%
Resolution 191.5 pulses/l
max. operating pressure 80 bar
max. peak pressure 100 bar
Fluid temperature -10°C...+80°C
Ambient temperature -10°C...+80°C
max. perm. foreign particle 20 µm
|
KRACHT
|
P.0139110001
Gear Type Flow Meter VCA 2 FC R1
Materials
Material housing Aluminium AlMgSiF30 hardcoated
Material Measuring unit Steel 1.7139
Material O-rings FKM
Bearing Multicomponent sleeve bearings (P10)
Product data
Pulse volume 2.0 cm³/pulse
Type of connection Pipe connection G3/4"
Electronic output 1 square wave signal
Electrical connection Rectangular connector - Terminal strip
Standard temperature execution
Supply voltage 24 V DC (12...30 V DC)
Specific data
Measuring range 1...65 l/min
Starting point at 0.12 l/min
Measuring accuracy +/- 2.5% of reading (at viscosity: min. 20
mm²/s)
Linearity +/- 0.1%
Resolution 500 pulses/l
max. operating pressure 160 bar
max. peak pressure 200 bar
Fluid temperature -10°C...+80°C
Ambient temperature -10°C...+80°C
max. perm. foreign particle 30 µm
|
KRACHT
|
P.0185520001
Gear Type Flow Meter VCG 2 FC P2
Materials
Material housing Spheroidal cast iron EN-GJS 400
Material Measuring unit Steel 1.7139
Material O-rings FKM
Bearing Multicomponent sleeve bearings (P10)
Product data
Pulse volume 2.0 cm³/pulse
Type of connection Plate mounting
Electronic output 2 squarewave signals, 90° shifted
Electrical connection Rectangular connector - Terminal strip
Standard temperature execution
Supply voltage 24 V DC (12...30 V DC)
Specific data
Measuring range 1...65 l/min
Starting point at 0.12 l/min
Measuring accuracy +/- 2.5% of reading (at viscosity: min. 20
mm²/s)
Resolution 500 pulses/l
max. operating pressure 315 bar
max. peak pressure 350 bar
Fluid temperature -15°C...+120°C
Ambient temperature -10°C...+80°C
max. perm. foreign particle 30 µm
|
Thứ Hai, 2 tháng 2, 2015
KRACHT VIET NAM
Đăng ký:
Đăng Nhận xét (Atom)
Hỗ trợ trực tuyến
Nguyễn Thị Xuân Đào - Sales Engineer
Chào mừng quý khách đã đến với tự động hóa
.
Hãy liên hệ ngay với chúng tôi để được hỗ trợ giá tốt nhất
email: kendy0209@gmail.com
Hotline: 0989.073.182 Skype: mskendy
email: kendy0209@gmail.com
Hotline: 0989.073.182 Skype: mskendy
Không có nhận xét nào:
Đăng nhận xét